Omron HEM-9000AI
Device Model:
HEM-9000AI
Manufacturer:
Omron Corporation, Kyoto Head Office, Shiokoji Horikawa, Shimogyo ku, Kyoto 600-8530, JAPAN.
Measuring functions:
Blood pressure
Primary Client Use:
Intended for professional use including central aortic pressure
Measurement Site:
Upper Arm
Measurement Occurrence:
Single and repeated measurements
Availability:
Available Currently
Device Manual:
Description:
The Omron HEM-9000AI is an automatic blood pressure monitor. Although its blood pressure measurement technology has been evaluated, it is not possible to base a determination on its accuracy from this research. Blood pressure measurements are taken from the upper arm. It is intended for professional use including central aortic pressure.
Assessment:
The technology used in the Omron HEM-9000AI, to measure blood pressure, has been assessed, in a general population, according to a non-standard protocol.
Recommendations:
Accuracy AssessmentRecommendationBasis
BP Medaval None When an evaluation is carried out using a non-standard protocol, no inference can be made on accuracy based on a standard protocol.
Validation Publications:

Ding FH, Fan WX, Zhang RY, Zhang Q, Li Y, Wang JG. Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. Am J Hypertens. 2011 Dec;24(12):1306-11. Epub: 2011 Oct 6. doi: 10.1038/ajh.2011.145. PMID: 21976274.

Ad Hoc protocol General population (Note: IA validation (n=33))

Relevant Publications:

Kips JG, Schutte AE, Vermeersch SJ, Huisman HW, Van Rooyen JM, Glyn MC, Fourie CM, Malan L, Schutte R, Van Bortel LM, Segers P. Comparison of central pressure estimates obtained from SphygmoCor, Omron HEM-9000AI and carotid applanation tonometry. J Hypertens. 2011 Jun;29(6):1115-20. doi: 10.1097/HJH.0b013e328346a3bc. PMID: 21505351.

Measurements from the Omron HEM-9000AI are compared to those from the Atcor Sphygmocor, though not in a formal validation.

Rezai MR, Goudot G, Winters C, Finn JD, Wu FC, Cruickshank JK. Calibration mode influences central blood pressure differences between SphygmoCor and two newer devices, the Arteriograph and Omron HEM-9000. Hypertens Res. 2011 Sep;34(9):1046-51. Epub: 2011 Jul 14. doi: 10.1038/hr.2011.75. PMID: 21753770. Available from: www.nature.com.

Measurements from the Omron HEM-9000AI are compared to those from the Arteriograph and the Sphygmocor, though not in a formal validation.

Ding FH, Li Y, Zhang RY, Zhang Q, Wang JG. Comparison of the SphygmoCor and Omron devices in the estimation of pressure amplification against the invasive catheter measurement. J Hypertens. 2013 Jan;31(1):86-93. doi: 10.1097/HJH.0b013e32835a8eca. PMID: 23188416.

Measurements from the Omron HEM-9000AI are compared to those from the Atcor Sphygmocor, though not in a formal validation.

Takase H, Dohi Y, Kimura G. Distribution of central blood pressure values estimated by Omron HEM-9000AI in the Japanese general population. Hypertens Res. 2013 Jan;36(1):50-7. Epub: 2012 Aug 16. doi: 10.1038/hr.2012.122. PMID: 22895062.

The publication describes the use of the Omron HEM-9000AI in a scientific study.