Device Model:
HEM-7320F
Manufacturer:
Omron Corporation, Kyoto Head Office, Shiokoji Horikawa, Shimogyo ku, Kyoto 600-8530, JAPAN.
Measuring functions:
Blood Pressure and PR
Primary Client Use:
Intended for self-measurement and home use
Measurement Site:
Upper Arm
Measurement Occurrence:
Single measurements only
Availability:
Discontinued but still available
Availability according to Countries or Regions:
Japan
Device Manual:
Description:
The Omron HEM-7320F is an automatic blood pressure monitor. Its blood pressure measurement technology has been proven to be accurate, with a certified 4-star Medaval rating. Blood pressure measurements are taken from the upper arm. It is intended for self-measurement and home use. This device has been discontinued by the manufacturer but may be available through certain outlets.
Assessment:
The accuracy of the technology used in the Omron HEM-7320F, to measure blood pressure, is certified by Medaval Ltd. It has passed in a clinical validation study, in a general population, according to a recognised standard protocol, as published in a peer-reviewed publication.
Recommendations:
| Accuracy Assessment | Recommendation | Basis |
| BP |
Medaval |
★★★★ Certified Accuracy |
Older clinical validation; recent protocol with certified adherence |
| BP |
BIHS (UK and IRL) |
Previous recommendation, now archived (Archived) |
Published evidence |
| BP |
ESH (Europe) |
Self-measurement |
Published evidence |
| BP |
Japanese Society of Hypertension |
Self-measurement (Previous: 2016-2018) |
Published evidence |
| BP |
Stride BP |
Self-measurement for adults (Unavailable) (Preferred) |
Published evidence |
Device Family:
Omron HEM-7320FJ,Y,
Omron HEM-7324CJ,
Omron HEM-8731J,
Omron HEM-7281TJ,
Omron HEM-7313J,
Omron HEM-7325TJ,
Omron HEM-7310J,
Omron HCR-7201J,
Omron HCR-7409J,
Omron HCR-7501TJ,
Omron HCR-7106J,
Omron HCR-7402Z,
Omron HCR-7502TZ,
Omron HCR-7602TZ,
Omron HEM-7320 (HEM-7320-AP)Y,
Omron HCR-7204TJ,
Omron HCR-7206T2J,
Omron HCR-7407J,
Omron HCR-7308T2J,
Omron HCR-7524TJ,
Omron HCR-7628TJLegend:
J JHS Implied Equivalence,
Y Internal declaration,
Z Almost Certain
Validation Publications:
Takahashi H, Yoshika M, Yokoi T. Validation of three automatic devices for the self-measurement of blood pressure according to the European Society of Hypertension International Protocol revision 2010: the Omron HEM-7130, HEM-7320F, and HEM-7500F. Blood Press Monit. 2015 Apr;20(2):92-7. doi: 10.1097/MBP.0000000000000096. PMID: 25462531.
ESH-IP:2010 - Pass General population
Medaval Certification Assessment
Medaval Ltd. Accreditation assessment of the blood pressure measurement technology used in the Omron HEM-7320F upper arm monitor, as validated according to the European Society of Hypertension International Protocol revision 2010. Medical Device Assessment. 2016 Aug 5;2016(1619) 5 p. Epub: 2019 Jan 31. Available from: www.medaval.ie.
With proven validity of validation results according to an accepted protocol, the clinical accuracy of the blood pressure measurement technology, used in the Omron HEM-7320F, is certified by Medaval Ltd.