📞  +353 1 6643768
 
📧  info@medaval.ie
A&D UA-766
Device Model:
UA-766
Manufacturer:
A&D Company Ltd., 3-23-14 Higashi-Ikebukuro, Toshima-Ku, 170-0013 Tokyo, JAPAN.
Measuring functions:
Blood pressure
Primary Client Use:
Intended for self-measurement and home use
Measurement Site:
Upper Arm
Measurement Occurrence:
Single measurements only
Availability:
Discontinued but still available
Availability according to Countries or Regions:
Japan
Description:
The A&D UA-766 is an automatic blood pressure monitor. The accuracy of its blood pressure measurement technology has yet to be proven to MDR requirements. Blood pressure measurements are taken from the upper arm. It is intended for self-measurement and home use. This device has been discontinued by the manufacturer but may be available through certain outlets.
Assessment:
The technology used in the A&D UA-766, to measure blood pressure, has been compared to a clinically validated device, but the results of the equivalence study have not been published and cannot be verified; nor can the protocol be checked for compliance with (EU) 2017/745 and MEDDEV 2.7/1 rev 4.
Recommendations:
Accuracy AssessmentRecommendationBasis
BP Medaval None Although equivalence to another device is claimed, this has not been tested to MDR requirements.
BP Japanese Society of Hypertension Self-measurement (Previous: 2016-2018) Implied equivalence to the A&D UA-767
Device Family:
Validation Publications for Equivalent Devices:

Note: This is a provisional list, as equivalence according to EU Regulation 2017/745 (e.g. MEDDEV 2.7/1 rev 4) is not proven. Accordingly, these publications are not used in the assessment of star-ratings.

A&D UA-767

Rogoza AN, Pavlova TS, Sergeeva MV. Validation of A&D UA-767 device for the self-measurement of blood pressure. Blood Press Monit. 2000 Aug;5(4):227-31. PMID: 11035865.

BHS:1993 - Pass (A/A) General population

SP10:1992 - Pass General population

A&D UA-767 Plus

Кобалава ЖД, Котовская ЮВ, Бабаева ЛА, Русакова ОС. [Kobalava ZD, Kotovskaia IV, Rusakova OS, Babaeva LA.] Валидация электронного полностью автоматического прибора UA-777 (A&D, Япония) для самоконтроля АД. [Validation of UA-767 Plus device for self measurement of blood pressure.] Клиническая фармакология и терапия [Clin Pharmacol Ther]. 2003;12(2):70-2. Available from: andyte.com.

BHS:1993 - Pass (A/A) General population

A&D UA-774

Verdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L, Porcellati C. Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure. Blood Press Monit. 2004 Aug;9(4):225-9. PMID: 15311150.

BHS:1993 - Pass (A/A) General population

A&D UA-779

Longo D, Bertolo O, Toffanin G, Frezza P, Palatini P. Validation of the A&D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance. Blood Press Monit. 2002 Aug;7(4):243-8. PMID: 12198341.

ESH-IP:2002 - Pass General population